IDC 엔지니어의 기술 이야기

Alteon 공장 초기화 본문

Network/Alteon

Alteon 공장 초기화

붉은볼곰팅이 2022. 2. 9. 10:17
반응형
Alteon L4 Config 리셋 (공장초기화)

>> Main# boot
------------------------------------------------------------
[Boot Options Menu]
      image   - Select software image to use on next boot
      conf    - Select config block to use on next boot
      gtimg   - Download new software image via TFTP
      ptimg   - Upload selected software image via TFTP
      reset   - Reset switch [WARNING: Restarts Spanning Tree]
      cur     - Display current boot options

>> Boot Options# conf
Currently set to use active config block on next boot.
Specify new block to use ["active"/"backup"/"factory"]:  factory  <----- 팩토리 셋팅
Next boot will use factory default config block instead of active.

>> Boot Options#

>> Boot Options#

>> Boot Options#

>> Boot Options# reset
Confirm clear all config regions [y/n]: y  <----------------------------- 재시작

Reset will use software "image1" and the factory default config block.
>> Note that this will RESTART the Spanning Tree,
>> which will likely cause an interruption in network service.
Confirm reset [y/n]: y